Flowchart of the disposal of the fire alarm of the duty officer in the control room

author:Jiang Feng's fire diary

As a duty officer in the control room, it is normal to receive several fire alarm false alarms a day, after all, it is an electronic product, the use time is long, the components are inevitably aging, and the smoke false alarm caused by small insects and dust is more common. In the face of the frequent false alarms of the daily monitoring host, it is easy to form a feeling of "wolf coming", resulting in laxity in thinking, paralysis, in case of encountering a real fire alarm, under the inertial thinking, it is easy to cause misjudgment of the fire and fire alarm, thus causing irreparable losses, bringing immeasurable consequences to yourself, to the leader, to all relevant responsible persons!

Flowchart of the disposal of the fire alarm of the duty officer in the control room

Shanghai Shengrui 4.22 fire alarm control room duty officer processing is very representative: at 13:29, set in the South Gate Guard Room of Shengrui Company fire automatic alarm control host alarm, showing "1st floor south area manual button fire alarm"; duty officer Wang Mou immediately used his mobile phone to shoot the alarm host screen and reported to the Ministry of Environmental Security through WeChat; during the period, the control host continued to alarm, but the fire control room duty personnel Wang Only operated the silence button of the control host. The automatic fire alarm control host was not switched from manual to automatic, nor was the 119 alarm dialed.

In the end, the fire became more and more fierce, resulting in 8 deaths (including two firefighters), direct economic losses of more than 31.13 million yuan, and the identification afterwards qualitatively analyzed the duty officer as: the staff of the fire control room was seriously derelict in duty. The fire control room did not implement the duty duty system, only one licensed personnel took up his post; when a fire broke out, the duty personnel did not immediately confirm the fire, did not call the alarm phone, did not transfer the fire alarm linkage control switch to the automatic state; the fire control room duty record had the phenomenon of others signing on behalf of others...

In the follow-up accountability, 11 people were criminally responsible, 29 people were jointly and severally responsible, and the attendant Wang Mou (who was the old king next door) seriously derelict his duties, failed to implement the emergency procedures for the fire control room duty in accordance with the regulations, and handled the emergency improperly. Direct responsibility for the occurrence of an accident ...

If the duty officer operates properly and operates strictly according to the norms, this fire can actually be another result. If we encounter such an unfortunate situation, as a duty officer in the control room, what kind of process should we follow? The following table, please download to your phone, save, read it every day, and keep it in mind!

Flowchart of the disposal of the fire alarm of the duty officer in the control room

The fire is fiercer than the tiger, and the prevention is in my heart!