天天看點

SUN V880 PCI I/O FAN tray 故障處理方案

Log摘要

System  Configuration:Oracle Corporationsun4u Sun Fire 880

System  clock frequency: 150 MHz

Memory  size: 8192 Megabytes

=========================  CPUs ===============================================

RunE$CPUCPU

BrdCPUMHzMB Impl.Mask

--- -----  ---- ---- ------- ----

A09008.0 US-III+2.3

B19008.0 US-III+2.3

A29008.0 US-III+2.3

B39008.0 US-III+2.3

=========================  Memory Configuration ===============================

LogicalLogicalLogical

MCBankBankBankDIMMInterleaveInterleaved

BrdIDnumsizeStatusSizeFactorwith

-------------------------------------------------------

A00512MBno_status256MB8-way0

A01512MBno_status256MB8-way0

A02512MBno_status256MB8-way0

A03512MBno_status256MB8-way0

B10512MBno_status256MB8-way1

B11512MBno_status256MB8-way1

B12512MBno_status256MB8-way1

B13512MBno_status256MB8-way1

A20512MBno_status256MB8-way0

A21512MBno_status256MB8-way0

A22512MBno_status256MB8-way0

A23512MBno_status256MB8-way0

B30512MBno_status256MB8-way1

B31512MBno_status256MB8-way1

B32512MBno_status256MB8-way1

B33512MBno_status256MB8-way1

=========================  IO Cards =========================

BusMax

IOPort BusFreq BusDev,

BrdTypeIDSide Slot MHzFreq Func State NameModel

---- ----  ---- ---- ---- ---- ---- ---- ----- ------------------------------------------------------

I/OPCI8B333332,0okSUNW,qlc-pci1077,2300.1077.106.1+

I/OPCI9B633332,0okSUNW,qlc-pci1077,2300.1077.106.1+

I/OPCI9B533333,0okSUNW,qlc-pci1077,2300.1077.106.1+

I/OPCI9B433334,0okSUNW,qlc-pci1077,2300.1077.106.1+

No failures  found in System

===========================

=========================  Environmental Status =========================

System  Temperatures (Celsius):

-------------------------------

DeviceTemperatureStatus

---------------------------------------

CPU069OK

CPU169OK

CPU270OK

CPU366OK

MB32OK

IOB29OK

DBP030OK

=================================

Front  Status Panel:

-------------------

Keyswitch  position: NORMAL

System LED  Status:

GEN FAULTREMOVE

[ ON][OFF]

DISK FAULTPOWER FAULT

[OFF][OFF]

LEFT THERMAL FAULT RIGHT THERMAL FAULT

LEFT DOORRIGHT DOOR

Disk  Status:

PresenceFault LEDRemove LED

DISK0: [PRESENT][OFF][OFF]

DISK1: [PRESENT][OFF][OFF]

DISK2: [PRESENT][OFF][OFF]

DISK3: [PRESENT][OFF][OFF]

DISK4: [PRESENT][OFF][OFF]

DISK5: [PRESENT][OFF][OFF]

DISK6: [EMPTY]

DISK7: [EMPTY]

DISK8: [EMPTY]

DISK9: [EMPTY]

DISK10: [EMPTY]

DISK11: [EMPTY]

Fan Bank :

----------

BankSpeedStatusFan State

( RPMS )

------------------------------

CPU0_PRIM_FAN2189[ENABLED]OK

CPU1_PRIM_FAN2290[ENABLED]OK

CPU0_SEC_FAN0[DISABLED]OK

CPU1_SEC_FAN0[DISABLED]OK

IO0_PRIM_FAN0[DISABLED]ERROR

IO1_PRIM_FAN0[DISABLED]ERROR

IO0_SEC_FAN3947[ENABLED]OK

IO1_SEC_FAN3896[ENABLED]OK

IO_BRIDGE_PRIM_FAN3333[ENABLED]OK

IO_BRIDGE_SEC_FAN0[DISABLED]OK

Power  Supplies:

---------------

Current Drain:

SupplyStatusFan FailTemp FailCS Fail3.3V5V12V48V

------------------------------------------------------

PS0GOOD6323

PS1GOOD6323

PS2GOOD6323

=========================  HW Revisions =======================================

System PROM  revisions:

----------------------

OBP 4.6.7  2002/07/24 15:42

IO ASIC  revisions:

------------------

Port

ModelIDStatus Version

--------  ---- ------ -------

Schizo8ok4

Schizo9ok4

# System  Configuration:Oracle Corporationsun4u Sun Fire 880

A2  9008.0 US-III+2.3

Brd IDnumsizeStatusSizeFactorwith

No failures found in System

#dmesg

Jan 15 11:39:50 csu picld[203]: [ID 625010  daemon.error] WARNING: Device IO0_PRIM_FAN failure detected

Jan 15 13:16:53 csu picld[208]: [ID 625010  daemon.error] WARNING: Device IO0_PRIM_FAN failure detected

Jan 15 14:46:34 csu picld[204]: [ID 625010  daemon.error] WARNING: Device IO0_PRIM_FAN failure detected

客戶反應,SUN V880前面闆,溫度LED訓示燈橙×××。

通過系統錯誤資訊得知:

通過dmesg 檢視出IO0_PRIM_FAN 檢查有問題,不排除IO1_PRIM_FAN和機器内部灰塵過多導緻.

是以,先準備2塊PCI I/O Fan Tray和吸塵器(有可能機器内部灰塵過多,導緻風扇告警),同時解決此次故障。

二.故障處理

注意

確定系統關機,電源斷開

SUN V880 PCI I/O FAN tray 故障處理方案

操作時,使用防靜電護腕

添加或更換硬體元件之前請作好資料備份。如果部件未正确安裝,則可能會導緻資料丢失。

準備确認項

類型

準備項

狀态

硬體

筆記本一台

已準備就緒

序列槽線一根

一字、十字螺絲刀各一把

防靜電護腕一個

新2塊IO_PRIM_FAN

軟體

其它

操作項清單

序号

操作項

操作内容

1

确認系統關機

建議客戶應用及業務資料備份

2

使用POST診斷

定位系統故障的确切位置

3

佩戴防靜電護腕

确認已經佩戴防靜電護腕,并且防靜電護腕連接配接到機櫃上的未塗漆部分

4

斷開電源

斷開主電源和次電源

5

移除服務檢修蓋

6

拆除處理器闆

7

将取下的處理器闆放置在防靜電的材質表面

8

拆開移除處理器前蓋

9

确認IO_PRIM_FAN位置

10

從防靜電包裝中取出IO_PRIM_FAN

11

安裝IO_PRIM_FAN

12

重新安裝處理器闆

13

确認故障影響消失

确認新更換的硬體無告警

确認新的硬體在系統中就緒

使用者确認應用及業務資料不受影響

14

收尾

清理現場,結束工作

三.參考資訊

SUN V880 PCI I/O FAN tray 故障處理方案
SUN V880 PCI I/O FAN tray 故障處理方案
SUN V880 PCI I/O FAN tray 故障處理方案