Log摘要
System Configuration:Oracle Corporationsun4u Sun Fire 880
System clock frequency: 150 MHz
Memory size: 8192 Megabytes
========================= CPUs ===============================================
RunE$CPUCPU
BrdCPUMHzMB Impl.Mask
--- ----- ---- ---- ------- ----
A09008.0 US-III+2.3
B19008.0 US-III+2.3
A29008.0 US-III+2.3
B39008.0 US-III+2.3
========================= Memory Configuration ===============================
LogicalLogicalLogical
MCBankBankBankDIMMInterleaveInterleaved
BrdIDnumsizeStatusSizeFactorwith
-------------------------------------------------------
A00512MBno_status256MB8-way0
A01512MBno_status256MB8-way0
A02512MBno_status256MB8-way0
A03512MBno_status256MB8-way0
B10512MBno_status256MB8-way1
B11512MBno_status256MB8-way1
B12512MBno_status256MB8-way1
B13512MBno_status256MB8-way1
A20512MBno_status256MB8-way0
A21512MBno_status256MB8-way0
A22512MBno_status256MB8-way0
A23512MBno_status256MB8-way0
B30512MBno_status256MB8-way1
B31512MBno_status256MB8-way1
B32512MBno_status256MB8-way1
B33512MBno_status256MB8-way1
========================= IO Cards =========================
BusMax
IOPort BusFreq BusDev,
BrdTypeIDSide Slot MHzFreq Func State NameModel
---- ---- ---- ---- ---- ---- ---- ---- ----- ------------------------------------------------------
I/OPCI8B333332,0okSUNW,qlc-pci1077,2300.1077.106.1+
I/OPCI9B633332,0okSUNW,qlc-pci1077,2300.1077.106.1+
I/OPCI9B533333,0okSUNW,qlc-pci1077,2300.1077.106.1+
I/OPCI9B433334,0okSUNW,qlc-pci1077,2300.1077.106.1+
No failures found in System
===========================
========================= Environmental Status =========================
System Temperatures (Celsius):
-------------------------------
DeviceTemperatureStatus
---------------------------------------
CPU069OK
CPU169OK
CPU270OK
CPU366OK
MB32OK
IOB29OK
DBP030OK
=================================
Front Status Panel:
-------------------
Keyswitch position: NORMAL
System LED Status:
GEN FAULTREMOVE
[ ON][OFF]
DISK FAULTPOWER FAULT
[OFF][OFF]
LEFT THERMAL FAULT RIGHT THERMAL FAULT
LEFT DOORRIGHT DOOR
Disk Status:
PresenceFault LEDRemove LED
DISK0: [PRESENT][OFF][OFF]
DISK1: [PRESENT][OFF][OFF]
DISK2: [PRESENT][OFF][OFF]
DISK3: [PRESENT][OFF][OFF]
DISK4: [PRESENT][OFF][OFF]
DISK5: [PRESENT][OFF][OFF]
DISK6: [EMPTY]
DISK7: [EMPTY]
DISK8: [EMPTY]
DISK9: [EMPTY]
DISK10: [EMPTY]
DISK11: [EMPTY]
Fan Bank :
----------
BankSpeedStatusFan State
( RPMS )
------------------------------
CPU0_PRIM_FAN2189[ENABLED]OK
CPU1_PRIM_FAN2290[ENABLED]OK
CPU0_SEC_FAN0[DISABLED]OK
CPU1_SEC_FAN0[DISABLED]OK
IO0_PRIM_FAN0[DISABLED]ERROR
IO1_PRIM_FAN0[DISABLED]ERROR
IO0_SEC_FAN3947[ENABLED]OK
IO1_SEC_FAN3896[ENABLED]OK
IO_BRIDGE_PRIM_FAN3333[ENABLED]OK
IO_BRIDGE_SEC_FAN0[DISABLED]OK
Power Supplies:
---------------
Current Drain:
SupplyStatusFan FailTemp FailCS Fail3.3V5V12V48V
------------------------------------------------------
PS0GOOD6323
PS1GOOD6323
PS2GOOD6323
========================= HW Revisions =======================================
System PROM revisions:
----------------------
OBP 4.6.7 2002/07/24 15:42
IO ASIC revisions:
------------------
Port
ModelIDStatus Version
-------- ---- ------ -------
Schizo8ok4
Schizo9ok4
# System Configuration:Oracle Corporationsun4u Sun Fire 880
A2 9008.0 US-III+2.3
Brd IDnumsizeStatusSizeFactorwith
No failures found in System
#dmesg
Jan 15 11:39:50 csu picld[203]: [ID 625010 daemon.error] WARNING: Device IO0_PRIM_FAN failure detected
Jan 15 13:16:53 csu picld[208]: [ID 625010 daemon.error] WARNING: Device IO0_PRIM_FAN failure detected
Jan 15 14:46:34 csu picld[204]: [ID 625010 daemon.error] WARNING: Device IO0_PRIM_FAN failure detected
客戶反應,SUN V880前面闆,溫度LED訓示燈橙×××。
通過系統錯誤資訊得知:
通過dmesg 檢視出IO0_PRIM_FAN 檢查有問題,不排除IO1_PRIM_FAN和機器内部灰塵過多導緻.
是以,先準備2塊PCI I/O Fan Tray和吸塵器(有可能機器内部灰塵過多,導緻風扇告警),同時解決此次故障。
二.故障處理
注意
確定系統關機,電源斷開

操作時,使用防靜電護腕
添加或更換硬體元件之前請作好資料備份。如果部件未正确安裝,則可能會導緻資料丢失。
準備确認項
類型
準備項
狀态
硬體
筆記本一台
已準備就緒
序列槽線一根
一字、十字螺絲刀各一把
防靜電護腕一個
新2塊IO_PRIM_FAN
軟體
其它
操作項清單
序号
操作項
操作内容
1
确認系統關機
建議客戶應用及業務資料備份
2
使用POST診斷
定位系統故障的确切位置
3
佩戴防靜電護腕
确認已經佩戴防靜電護腕,并且防靜電護腕連接配接到機櫃上的未塗漆部分
4
斷開電源
斷開主電源和次電源
5
移除服務檢修蓋
6
拆除處理器闆
7
将取下的處理器闆放置在防靜電的材質表面
8
拆開移除處理器前蓋
9
确認IO_PRIM_FAN位置
10
從防靜電包裝中取出IO_PRIM_FAN
11
安裝IO_PRIM_FAN
12
重新安裝處理器闆
13
确認故障影響消失
确認新更換的硬體無告警
确認新的硬體在系統中就緒
使用者确認應用及業務資料不受影響
14
收尾
清理現場,結束工作