Log摘要
System Configuration:Oracle Corporationsun4u Sun Fire 880
System clock frequency: 150 MHz
Memory size: 8192 Megabytes
========================= CPUs ===============================================
RunE$CPUCPU
BrdCPUMHzMB Impl.Mask
--- ----- ---- ---- ------- ----
A09008.0 US-III+2.3
B19008.0 US-III+2.3
A29008.0 US-III+2.3
B39008.0 US-III+2.3
========================= Memory Configuration ===============================
LogicalLogicalLogical
MCBankBankBankDIMMInterleaveInterleaved
BrdIDnumsizeStatusSizeFactorwith
-------------------------------------------------------
A00512MBno_status256MB8-way0
A01512MBno_status256MB8-way0
A02512MBno_status256MB8-way0
A03512MBno_status256MB8-way0
B10512MBno_status256MB8-way1
B11512MBno_status256MB8-way1
B12512MBno_status256MB8-way1
B13512MBno_status256MB8-way1
A20512MBno_status256MB8-way0
A21512MBno_status256MB8-way0
A22512MBno_status256MB8-way0
A23512MBno_status256MB8-way0
B30512MBno_status256MB8-way1
B31512MBno_status256MB8-way1
B32512MBno_status256MB8-way1
B33512MBno_status256MB8-way1
========================= IO Cards =========================
BusMax
IOPort BusFreq BusDev,
BrdTypeIDSide Slot MHzFreq Func State NameModel
---- ---- ---- ---- ---- ---- ---- ---- ----- ------------------------------------------------------
I/OPCI8B333332,0okSUNW,qlc-pci1077,2300.1077.106.1+
I/OPCI9B633332,0okSUNW,qlc-pci1077,2300.1077.106.1+
I/OPCI9B533333,0okSUNW,qlc-pci1077,2300.1077.106.1+
I/OPCI9B433334,0okSUNW,qlc-pci1077,2300.1077.106.1+
No failures found in System
===========================
========================= Environmental Status =========================
System Temperatures (Celsius):
-------------------------------
DeviceTemperatureStatus
---------------------------------------
CPU069OK
CPU169OK
CPU270OK
CPU366OK
MB32OK
IOB29OK
DBP030OK
=================================
Front Status Panel:
-------------------
Keyswitch position: NORMAL
System LED Status:
GEN FAULTREMOVE
[ ON][OFF]
DISK FAULTPOWER FAULT
[OFF][OFF]
LEFT THERMAL FAULT RIGHT THERMAL FAULT
LEFT DOORRIGHT DOOR
Disk Status:
PresenceFault LEDRemove LED
DISK0: [PRESENT][OFF][OFF]
DISK1: [PRESENT][OFF][OFF]
DISK2: [PRESENT][OFF][OFF]
DISK3: [PRESENT][OFF][OFF]
DISK4: [PRESENT][OFF][OFF]
DISK5: [PRESENT][OFF][OFF]
DISK6: [EMPTY]
DISK7: [EMPTY]
DISK8: [EMPTY]
DISK9: [EMPTY]
DISK10: [EMPTY]
DISK11: [EMPTY]
Fan Bank :
----------
BankSpeedStatusFan State
( RPMS )
------------------------------
CPU0_PRIM_FAN2189[ENABLED]OK
CPU1_PRIM_FAN2290[ENABLED]OK
CPU0_SEC_FAN0[DISABLED]OK
CPU1_SEC_FAN0[DISABLED]OK
IO0_PRIM_FAN0[DISABLED]ERROR
IO1_PRIM_FAN0[DISABLED]ERROR
IO0_SEC_FAN3947[ENABLED]OK
IO1_SEC_FAN3896[ENABLED]OK
IO_BRIDGE_PRIM_FAN3333[ENABLED]OK
IO_BRIDGE_SEC_FAN0[DISABLED]OK
Power Supplies:
---------------
Current Drain:
SupplyStatusFan FailTemp FailCS Fail3.3V5V12V48V
------------------------------------------------------
PS0GOOD6323
PS1GOOD6323
PS2GOOD6323
========================= HW Revisions =======================================
System PROM revisions:
----------------------
OBP 4.6.7 2002/07/24 15:42
IO ASIC revisions:
------------------
Port
ModelIDStatus Version
-------- ---- ------ -------
Schizo8ok4
Schizo9ok4
# System Configuration:Oracle Corporationsun4u Sun Fire 880
A2 9008.0 US-III+2.3
Brd IDnumsizeStatusSizeFactorwith
No failures found in System
#dmesg
Jan 15 11:39:50 csu picld[203]: [ID 625010 daemon.error] WARNING: Device IO0_PRIM_FAN failure detected
Jan 15 13:16:53 csu picld[208]: [ID 625010 daemon.error] WARNING: Device IO0_PRIM_FAN failure detected
Jan 15 14:46:34 csu picld[204]: [ID 625010 daemon.error] WARNING: Device IO0_PRIM_FAN failure detected
客户反应,SUN V880前面板,温度LED指示灯橙×××。
通过系统错误信息得知:
通过dmesg 查看出IO0_PRIM_FAN 检查有问题,不排除IO1_PRIM_FAN和机器内部灰尘过多导致.
因此,先准备2块PCI I/O Fan Tray和吸尘器(有可能机器内部灰尘过多,导致风扇告警),同时解决此次故障。
二.故障处理
注意
确保系统关机,电源断开

操作时,使用防静电护腕
添加或更换硬件组件之前请作好数据备份。如果部件未正确安装,则可能会导致数据丢失。
准备确认项
类型
准备项
状态
硬件
笔记本一台
已准备就绪
串口线一根
一字、十字螺丝刀各一把
防静电护腕一个
新2块IO_PRIM_FAN
软件
其它
操作项列表
序号
操作项
操作内容
1
确认系统关机
建议客户应用及业务数据备份
2
使用POST诊断
定位系统故障的确切位置
3
佩戴防静电护腕
确认已经佩戴防静电护腕,并且防静电护腕连接到机柜上的未涂漆部分
4
断开电源
断开主电源和次电源
5
移除服务检修盖
6
拆除处理器板
7
将取下的处理器板放置在防静电的材质表面
8
拆开移除处理器前盖
9
确认IO_PRIM_FAN位置
10
从防静电包装中取出IO_PRIM_FAN
11
安装IO_PRIM_FAN
12
重新安装处理器板
13
确认故障影响消失
确认新更换的硬件无告警
确认新的硬件在系统中就绪
用户确认应用及业务数据不受影响
14
收尾
清理现场,结束工作
三.参考信息