The actual cutting size of the laser cutting machine does not match the size of the design drawing
Original design size: width 50mm
Processing size: width 76mm (26mm larger than the design drawing)
<h1 class="pgc-h-arrow-right" data-track="4" > the cause of the failure</h1>
<h1 class="pgc-h-arrow-right" data-track="5" > 1.X/Y axis motor has an incorrect pulse setting</h1>
Workaround:
(1) Click "File" "Manufacturer Parameters"
(2) Enter the password: "TL9501" and click "OK"
(3) Enter the manufacturer's parameters page and click "Read"
(4) Click "Correct XY Step Distance" to enter the correction page
(5) Click in turn according to the picture steps, after the calibration graphic cutting is completed, measure the calibration graphic size, and enter, click OK to complete the calibration
(6) After the calibration is completed, click the "Reset" button in the control panel, then draw a new square of 150×150mm, cut again, if the actual measured size is correct, the problem is solved. Instead, repeat step 5