天天看点

SAP PARAMETER之User security相关

Simple changes can rise your system security. Usage of SAProuter is a good choice when correctly implemented. Login through SAP LogonPad (from version 3.0f onwards) improve the access control. SAP profile parameters shall also contain:

Rdisp/gui_auto_logout = 1800

The user connection is closed after 30 minutes without usage. This parameter is deactivated by setting the value to 0.

Login/fails_to_session_end = 3

After 3 wrong password the connection is automaticly closed.

The default value is 3, can set it to any value between 1 and 99

Login/fails_to_users_lock = 5

After 5 wrong password the user is locked. The default value is 12. Possible values are form 1 to 99.

Login/min_password_lng = 6

Password length at least 6 characters.

Login/password_expiration_time = 90

Password expires after 3 months.

login/system_client

login/no_automatic_user_sapstar

Disables special properties for for user SAP*, when this parameter is set to a value greater than 0

auth/no_check_in_some_cases

This parameter is set to switch off special authorization checks by customers and is the main parameter for activating the Profile Generator Tool. Values can be either Y(yes) or N(no)

对于Parameter : auth/no_check_in_some_cases再看看更详细的说明 《Note:416016》

Parameter description :

This parameter must be set to "Y" if you are using the profile generator.

The profile generator uses the authorization default values that you can manage with Transaction SU24.This transaction is also used to suppress certain authorization checks for selected transactions.

继续阅读