<a href="http://www-01.ibm.com/support/docview.wss?uid=swg21368020">http://www-01.ibm.com/support/docview.wss?uid=swg21368020</a>

Attempts to start IBM WebSphere Application Server (WAS) v6.1.x through Rational Application Developer for WebSphere Software (RAD) v7.0.x results in the error ADMU7704E: Failed while trying to start the Windows Service associated

with server.

Complete error while starting WebSphere Application Server (WAS) v6.1.x:

<code>ADMU7704E: Failed while trying to start the Windows Service associated with server: server1; probable error executing WASService.exe: Starting Service: [service name] Timed out waiting for service to respond to command, after 60 seconds.Failed to start service, or timed out while waiting for start to complete. Check the logs for details.</code>

The server was configured as a Windows Service.

If this was unintentional, create a new server profile that does not run the application as a Windows Service.

Steps describing how to do this can be found in the Related URL section.

Alternatively, you can do the following:

Open Windows Services Control Panel (Start &gt; Settings &gt; Control Panel &gt; Administrative Tools &gt; Services).

Look for the service name of WAS V6.1:

"IBM WebSphere Application Server V6.1 - [service_name]".

Open a command window and go to [RAD_Installation]\runtimes\base_v61\bin

Run the command:

WASService.exe -remove [service_name]

You should see a message "Successfully removed service".

Restart RAD and you should now be able to successfully start your WASv6.1.x server.