亞馬遜美國站針對部分賣季節性/裝飾性燈具産品的商家要求提供UL588相關資料,以證明燈具産品的安全性。
亞馬遜郵件: This product has been identified a light that is not compliant with 16 CFR 1120.3(c). Amazon policy requires that listings for all lights comply with 16 CFR 1120.3(c). If your product has been tested and confirmed to comply with 16 CFR 1120.3(c), please create a new listing with updated photos.
翻譯為:本産品已被鑒定為不符合16 CFR 1120.3(c)的燈。 亞馬遜政策要求所有燈的清單符合16 CFR 1120.3(c)。 如果您的産品已經過測試并确認符合16 CFR 1120.3(c),請建立一個新的清單,并更新照片。
也就說,燈具類,裝飾性照明産品,例如燈串,小燈泡,霓虹燈管等需要滿足16 CFR 1120.3(c)條件。
那麼16CFR1120.3(c)是什麼?簡單來說16 CFR 1120.3(c)是UL588裡面的3個要求!原文:Seasonal and decorative lighting products that lack one or more of the following characteristics in conformance with requirements in sections 6, 7, 15, 71, 79, and SB15 of UL 588 (incorporated by reference, see § 1120.4):
(1) Minimum wire size requirements in section 6 of UL 588;外部線要符合UL588标準要求,串聯的燈小22AWG的線;并聯的燈小20AWG.
(2) Sufficient strain relief requirements in sections 15, 71, 79, and SB15 of UL 588;根據UL588标準做一個電源線拉力測試
(3) Overcurrent protection requirements in section 7 of UL 588.過流保護,産品需要有一個保險絲!
UL588覆寫的範圍:串聯燈串、并聯燈串、裝飾燈、燈串帶套花、雪屋、架構燈、鐵架燈、燭台燈、閃爍控制器,豬尾巴。
UL588所涉及的範圍不包括水管等和小夜燈。
小燈串結構:燈串一定要在10燈以上,燈泡額定電壓計算方式12Volt=120Volt/10燈
根據不同的燈串,測試項目也有不同的差別。
1、帶有聚合物外殼的燈串
(1)外売模具應力消除測試
(2)跌落測試
(3)沖擊測試
(4)冷沖擊試驗
(5)耐壓測試
(6)粘合力測試
2、使用過電流保護裝置的燈串
(1)校準測試
(2)故障電流測試
(3)保險絲座溫度測試
(4)保險絲座壓碎測試
(5)保險絲座覆寫測試
3、使用有線連接配接的裝置或電源插座的産品
(1)應變消除測試
(2)導體連接配接可靠性測試
(3)刀片安全性測試
(4)輸入觸點的安全性測試
(5)絕緣測試的安全性
(6)輔助功能測試
4、裝飾品燈串
(1)漏電流測試
(2)200mA下的溫度測試(電子操作)
(3)外殼模具應力消除測試
(4)應力消除測試
(5)跌落測試
(6)大電流異常測試