當磁盤label version過高時,在添加磁盤時會有如下提示: | [sc-gxfc2050-A:raid.assim.disk.badlabelversion:error]: Disk 0c.01.14 Shelf 1 Bay 14[NETAPP X287_HVPBP288A15 NA00] S/N [JLVA02EC] has raid label withversion (9), which is not within the currently supported range (5 - 8). Pleasecontact Network Appliance Global Services. [sc-gxfc2050-A:raid.config.disk.bad.label.version:error]: Disk 0c.01.14 Shelf 1 Bay 14[NETAPP X287_HVPBP288A15 NA00] S/N [JLVA02EC] has an unsupportedlabel version. |
label version資訊: | Broken disks RAIDDisk Device HA SHELF BAYCHAN Pool Type RPM Used (MB/blks) Phys (MB/blks) --------- ------ ------------- -------- ---- ----- -------------- label version 0c.01.12 0c 1 12 SA:1 - SAS 15000272000/557056000 274845/562884296 label version 0c.01.13 0c 1 13 SA:1 - SAS 15000272000/557056000 274845/562884296 label version 0c.01.14 0c 1 14 SA:1 - SAS 15000272000/557056000 274845/562884296 label version 0c.01.16 0c 1 16 SA:1 - SAS 15000272000/557056000 274845/562884296 label version 0c.01.17 0c 1 17 SA:1 - SAS 15000272000/557056000 274845/562884296 |
解決方法有: | |
更新OS版本 | 通過對現有ONTAP OS系統更新,來直接支援labelversion值是9的磁盤。(會影響生産,需要提供更新視窗) |
将磁盤的 labelversion降級 | 将磁盤插入同類型磁盤架空槽位: >sysconfig (檢視sysid) >disk assign disk_id –snew_sysid –f (指定磁盤屬于新的機頭) >sysconfig –r (檢視該磁盤已經屬于spare盤) 這時也可以在進階模式下, 通過label summary可以看到spare盤label version為0 v5.20: :Invalid Label! CRC0x9d94b571, mgc 0x0, lbl V0, sz 0 , flags 0x0 SPARE >disk remove_ownershipdisk_id (删除該磁盤的owner_ship) >disk remove disk_id(移除spare盤) 取出spare盤 如果有多塊磁盤,重複上面動作。 |
另一種方法, 是在系統維護模式下lable: | 将磁盤插入同類型磁盤架空槽位 關機進入維護模式,開機提示Ctrl+C for boot menu,按Ctrl + C進入啟動菜單,按數字5進入維護模式 >label makespare disk_id (強制磁盤成為spare盤,可以重複該指令對多塊新加磁盤操作) >label summary (檢視labelversion是否已經為0) >disk remove_ownership (删除owner_ship) >disk remove disk_id (移除spare盤) |